AQ1000 Optical Time Domain Reflectometer
Product Introduction
This AQ1000 is specifically designed to increase the productivity of field personnel working on the installation and deployment of optical access networks such as Fiber To The Home (FTTH). Although it is positioned as an entry-level model, it still retains Yokogawa’s established standards of quality/reliability and features characteristics which are usually present in higher-level models, such as a high-quality capacitive multi-touch touchscreen and wireless connectivity.
Function characteristics:
The AQ1000 satisfies test and measurement needs in analyzing access optical networks.
1. Multi-touch touchscreen Intuitive and responsive
2. One-button measurement
3.Long battery operation time,Over 10 hours
4.OTDR view modes: Trace view & Map view
5.Quick boot-up: From completely OFF to measurement ready in under 10 seconds
6.Built-in Power checke(PC) and Light source(LS), and Visible light source(VLS)
7.USB power feeding: USB port is used for charging the battery of AQ1000.
9.Data handling features,Direct data saving
Items | Specifications | |
Display | 5.0 TFT LCD(resolution 800*480,Capacitive touch screen) | |
External interface | USB2.0*2(Type A *1:主机、microB *1:USB)、DC power | |
WIfi LAN(/WLN):IEEE802.11b/g/n | ||
Dimensions | Approx 185mm(W)*116mm(H)*56mm(D) | |
Weight | Approx 660g | |
Wavelength (nm) | 1310±20/1550±20 | |
Applicable fiber | SM(ITU-T G.652) | |
Distance range(km) | 0.2,0.5,1,2,5,10,20,30,50,100,200,256 | |
Pulse width(ns) | 3,10,20,30,50,100,200,300,500,1000,2000,5000,10000, 20000 | |
Sampling resolution | Min 125px | |
Number of sampling points | Max 256000 | |
Distance measurement accuracy(m) | ±(1m + Measurement distance *2*10¯5±1 Measurement distance) | |
Event dead zone(m) | ≤0.8 | |
Attenuation dead zone (m) | 4/5 | |
Dynamic range(dB) | 32/30 | |
Loss measurement accuracy | ±0.03dB/dB | |
Return loss measurement accuracy | ±2dB | |
Laser class | Class 1M |
Optical Time Domain Reflectometer
Light Source And Optical Power Meter